Flake Ice Machine LIF-200KHome > Products > Flake Ice Machine> Medium Capacity
  • Main Features
  • Specifications
  • Download
  • Layouts
  • Performance Parameters
  • High efficiency heat transfer technology;
  • Spiral blade design decreases resistance and friction, flake ice 100% fall off;
  • Specialized processing technology ensures long service time evaporator;
  • Easy installation, ready to use after water and electric plug in;
  • Reliable operation, little maintenance;
  • Compact design, less space required;
  • Hygienically designed without hidden spots and bacteria-harboring areas for easy inspection and cleaning.

Specification of Flake Ice Machine LIF-200K

Item Specification Unit
Power supply 380V/3P/50Hz Voltage/Phase/Frequency
Refrigerant R22/R404A
Daily capacity 20ton/day
Cooling mode Water-cooled
Standard condition Ambient temperature 35
Water inlet temperature 25
Operating power Compressor 17.1X3 kw
Condenser fan 1.5 kw
Cooling tower pump 3.7 kw
Reducer 1.5 kw
Cooling water pump 0.55 kw
Average total 58.75 kw
Total install power 78 kw
Compressor Refrigeration capacity 38X3 kw
Condensing temperature 38
Evaporating temperature -23
COP. 2.22 kw/kw
Horse power 34X3 HP
Ice machine dimension Size 4900×1680×2490 (L×W×H)(mm)
Net weight 3490 kg
Pipe size 3/4" inch
Water supply pressure requirement 1~6 bar
Cooling tower module size Cooling tower size ∅2175x2565 (O.D.×H)(mm)
Feed pipe size 3/4'' inch
Cooling water pipe size 4'' inch
Operating weight 1120 Kg
Parts info Compressor Bitzer, Germany
Expansion valve ALCO, United States
Stop valve DANFOSS, Denmark
Solenoid valve DANFOSS, Denmark
Filter ALCO, United States
Button/indicator Schneider, France
Electrical Schneider, France
PLC SIEMENS, Germany

Note: Actual Production= Theory Production×WT×AT

Linsky ice machine production will be affected by environment. The main factors are ambient temperature and water inlet temperature. Based on long term actual experiment, Linsky records precise experiment data and conclude chart WT and AT.

When water inlet temperature exceeds 30℃, it is suggested to pre-cool the water by chiller.
When ambient temperature exceeds 45℃, it is suggested to use water-cooled condenser or tailor made your machine.